Product for pc Product for mobile
>
Telecom Power System
Share to

Eltek Rectiverter 2U 6kVA Eltek Flatpack Power System With Smartpack2 Touch Controller CIOR0402.1XXX

Eltek Rectiverter 2U 6kVA Eltek Flatpack Power System With Smartpack2 Touch Controller CIOR0402.1XXX

Place of Origin: CN
Brand Name: Eltek
Certification: CE,UL
Model Number: CIOR0402.1xxx
Packaging Details: Carton pacaked
Delivery Time: 8-10 weeks
Payment Terms: L/C,T/T
Supply Ability: 500 sets per month

Get Best Price
Detailed
Showcase

Specifications

CategoryItemDetails
Models8 kW, 230 VAC4 kW, 115 VAC
Product familyCIOR0402.1xxxCIOR0402.1xxx
Voltage (default) / (adjustable range) 1)230 VAC / 200-240 VAC115 VAC / 100-127 VAC
Frequency (inverter mode – default)50 Hz (adaptive)60 Hz (adaptive)
Frequency (inverter mode – settable)50 Hz, 60 Hz or last synced 50 / 60 Hz (adaptive)
Power maximum (continuous / overload <15s)4800 W (6000 VA) / 8000 VA2400 W (3000 VA) / 4000 VA
Current maximum (continuous / overload <15s)26 ARMS / 34,8 ARMS
Current (maximum) quick trip (20ms)128 A (6 x nominal)
Hold up (Voltage dips) (before switching to battery)5 ms5 ms
THD< 1,5 % at resistive load
ProtectionFuse in L, Hot pluggable, Varistor
Voltage (default) / (adjustable range)245 VDC / 194-290 VDC
Power (maximum @nominal input)4800 W 2)2400 W 2)
Current (maximum @VOUT ≤ 108 VDC)22,2 A 2)11,1 A 2)
Current sharing (10 - 100% load)±5 % of maximum current from 10 to 100 % load
ProtectionShort circuit proof, Over voltage shutdown, Reversed polarity and Fuse
AC Mains Input Voltage (range / LV disconnect)185-275 VAC / 170 VAC95-140 VAC / 85 VAC
AC Current (maximum - depends on module type)32,8-46 ARMS 3)36,8-45,2 ARMS 3)
Frequency (default: sync range)47-53 & 57-63 Hz57-63 & 47-53 Hz
Frequency (settable: sync range)47-53 Hz, 57-63 Hz or both (adaptive)
Power Factor / THD> 0,99 at 50% load or more / < 3,5 %
DC Voltage nominal / extended range4)204-290 VDC / 180-204 VDC
DC Current (maximum)26,7 A / 36 A during overload (15 s)12,8 A / 18 A during overload (15 s)
Input featuresFuse in L and N, Hot pluggable, Varistor AC input individual screw terminals 4 mm2 for L, N & PE (4x single phase)
Control and Monitoring (master unit)Smartpack2 Touch
Control and Monitoring (basic unit)Smartpack2 Basic Industrial
Controller CAN nodeFleximonitor (with Relay box)
AC distributionAC output individual screw terminals 10 mm2 for L, N & PE (1x single phase)
DC distributionDC bulk connection on 2x M6 bolt
Efficiency> 96 % (mains mode), > 95 % (inverter mode)> 93 % (mains mode), > 92 % (inverter mode)
Operating temperature-40 to +55 °C (-40 to +131 °F), humidity 5-95 % RH non-condensing
Storage temperature-40 to +85 °C (-40 to +185 °F), humidity 0-99 % RH non-condensing
Dimensions [W x D x H]482 x 440 x 89 mm (2U) (19 x 17,3 x 3,5 inch)
Weight9,9 kg (21,8 lbs)
Electrical safetyEN 60950-1, EN 62040-1 UPS safety
EMCETSI EN 300 386 V2.1.1, FCC CFR 47 Part 15 EN 62040-2 EN 61000-6-1/-2/-3/-4/-5
EnvironmentETSI EN 300 019: 2-1 (Class 1.2), 2-2 (Class 2.3) & 2-3 (Class 3.2) Normal operating conditions as per IEC 62040-3:2011 clause 4.2. Other operating conditions as per IEC 62040-3:2011 clause 4.3, must be advised RoHS 3 (2015/863/EU) and WEEE (2008/98/EC) compliant
1) Output voltage ranges configured in factory and have individual keying in top chassis 3) If DC port is overloaded pulling the voltage below 194 V the input current may increase above this level.2) AC load has priority. Maximum available DC output power and current is dependent on instant AC load and AC input voltage; i.e. maximum 3200 W / 29,6 A at full AC power and nominal input for 230 VAC. 4) Reduced performance - no over load support, and for 200-240 VAC output THD will increased and maximum output power de- rates (to 970 W for 230 VAC @ 180 VDC)

Highlight: Eltek Rectiverter 2U Smartpack2 CIOR0402.1, eltek flatpack power system 2U 6kVA, Eltek Rectiverter 2U 6kVA

Eltek Rectiverter 2U 6kVA Eltek Flatpack Power System With Smartpack2 Touch Controller CIOR0402.1XXX

Product Description

Eltek Rectiverter 2U, 6kVA Integrated System 220 VDC Systems with Smartpack2 Touch & Basic Industrial CIOR0402.XXX

The rectinverter 2U 19 inch integrated system can be used as standar lone system with bulk AC &DC outputs in industrial applications where a 230 /115Vac and 220Vdc back up is needed.

The total output power for both AC and DC is limisted to a total 8KW, AC and DC output limits can be set according to the connected load where the limitation for AC load is set to max 6kVA and for DC load to max 4KW and 8KW.

Ad additional options, the measuring and signaling can be widely extended with the flexmonitor CAN node.

TELECOM-MOBILE/WIRELESS

LTE/4G/WiMAX

Distributed antenna system

Broadband

Radio base stations/cell sites

POWER UTILITIES

Low & High voltage switchgear

Transformer & SUB stations

Control & protection

SCADA system

RAILWAY & METRO INFRASTRUCTURE

Control & protection

Signaling

Key Features

Compact design and simple installation

Single phase 230 or 115VAC input and output

48Vdc input and output

Up to 4 rectiverter modules

8KW total AC+DC output

Max 6kVA AC output

Max 4KW/ 8KW DC output

1 or 2 pole AC distribution options

1 Pole DC distribution option

Built in transfer technology

Techinical Data

Product Display

Related Products

Why Choose Us

Loading...