Eltek Flatpack S 36V/1000W HE UI Rectifier Module Part No 241123.235

Eltek Flatpack S 36V/1000W HE UI Rectifier Module Part No 241123.235

Place of Origin: CN
Brand Name: Eltek
Certification: CE, UL
Model Number: 241123.235
Packaging Details: cartons
Delivery Time: 8-10 weeks
Payment Terms: L/C,T/T
Supply Ability: 3000 pieces per month

Get Best Price
Detailed
Showcase

Specifications

ItemDetails
Model36/1000 HE UI
Part number241122.235
Voltage (nominal)185 - 400 VDC / 185 - 275 VAC
Voltage (operating range)85 - 400 VDC / 85 - 305 VAC
FrequencyDC, 16 2/3 Hz, 45 - 66 Hz
Current (maximum)5.9 ADC / 5.9 ARMS
ProtectionFuse in Positive & Negative, Reversed polarity insensitive, Shutdown above 420 VDC / 305 VAC
Voltage40 VDC
Voltage (adjustable range)331) - 45 VDC
Power (maximum) @ nominal input1000 W / 450 W @16 2/3 Hz input
Power (maximum) @ 85 VDC / 85 VAC input440 W / 440 W
Current (max cont.) @ nominal input27.8 A (@VOUT < 36 VDC)
Hold up time, maximum output power>10ms; output voltage > 33 VDC
Current sharing (10 - 100% load)±5% of maximum current from 10 to 100% load
Static Voltage regulation (10 - 100% load)±0.5%
Dynamic Voltage regulation±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms
Ripple< 150 mVPP , 30 MHz bandwidth
ProtectionORing FET Short circuit proof High temperature protection Over voltage Shutdown
Efficiency> 95 %
Isolation4.2 kVDC - input to output 2.25 kVDC - input to earth 710 VDC - output to earth
Alarms: Red LEDLow and high input voltage, High and low temperature shutdown, Rectifier Failure, Overvoltage shutdown on output, Fan failure when fan stops, Low output voltage alarm, CAN bus failure
Warnings: Yellow LEDRectifier in power de-rate mode, Remote output current limit activated, Input voltage out of range, flashing at overvoltage, Loss of CAN communication with controller
Alarm relay (NO - opens when de-energized)Opens on Alarms and missing input voltage.
MTBF (Telcordia Issue 3 & Method II Case L1)>2 700 000 (@ Tambient : 25 °C)
Operating temperature (5-95% RH n.cond. hum.) Maximum output power de-rates above temp / to-40 to + 85°C [-40 to +185°F] 45°C [140°F] / 400W @ 85°C [185°F]
Storage temperature-40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing
Dimensions[WxHxD] / Weight72 x 40 x 217mm2) (2.84 x 1.57 x 8.54”)2) / < 850 g (1.9 lbs)
Electrical safetyEN 60950-1:2006+A11:2009+A1:2010+A12:2011
EMCEN 61000-6-1:2007, -6-2:2005, - 6-3:2007 + A1:2010, - 6-4:2007 + A1:2010 EN 50121-1:2015, -2:2015, -4:2015, -5:2015
EnvironmentETSI EN 300 019: 2-1 (Class 1.2), 2-2 (Class 2.3) & 2-3 (Class 3.2) RoHS (2011/65/EU) and WEEE (2012/19/EU) compliant

Highlight: HE UI Rectifier Module 241123.235, HE UI Rectifier Module, Eltek Flatpack S HE UI

Eltek Flatpack S 36V/1000W HE UI Rectifier Module Part No 241123.235

Product Description

Eltek Flatpack S 36V/1000W HE UI Rectifier Module (Part No.: 241123.235)

Flatpack S 36V/1000W HE UI

Applications in these markets demand state of the art, reliable and safe DC power systems. Flatpack S delivers an industry leading power density in its segment, many safety functions, wide operating temperature range and superb reliability in its small 217mm deep housing.

Compact and reliable rectifier for rail and power utilities applications

Used in the 3U rack with Smartpack S controller, the Flatpack S rectifiers cover 2 to 8kW applications using a minimum of space, less than 18 liters, and low heat dissipation.

Key Features

Small

Short

Power dense, 26 W/inch3

High efficiency

OR-ing protection on output

Wide AC and DC input range

Hot pluggable

Voltage keying

Rail EMC certification