Product for pc Product for mobile
>
Telecom Power System
Share to

3kVA 1phase 220VDC Telecom Power System Rectiverter Integrated Standalone (Part No.:CTOR0201.003)

3kVA 1phase 220VDC Telecom Power System Rectiverter Integrated Standalone (Part No.:CTOR0201.003)

Place of Origin: CN
Brand Name: Eltek
Certification: CE,UL
Model Number: CTOR0201.003
Packaging Details: Carton pacaked
Delivery Time: 8-10 weeks
Payment Terms: L/C,T/T
Supply Ability: 500 sets per month

Get Best Price
Detailed
Showcase

Specifications

CategoryItemDetails
Models / ordering information4 kW, 230 V2 kW, 115 V
Part numberCTOR0201.003CTOR0201.006
Voltage (default) / (adjustable range)1)230 VAC / 200 - 240 VAC115 VAC / 100 - 127 VAC
Frequency (default inverter mode)50 Hz (adaptive)60 Hz (adaptive)
Frequency (set-able inverter mode)50Hz, 60Hz or last synced 50/60Hz (adaptive)
Power maximum (continuous / overload (<15s) )2400 W (3000 VA) / 4000 VA1200 W (1500VA) / 2000 VA
Current maximum (continuous / overload (<15s) )13ARMS / 17,4ARMS
Current (maximum) Quick trip (20ms)64 A (6 x nominal)
Hold up (Voltage dips) (before switching to battery)5 ms
THD< 1.5 % at resistive load
Output featuresFuse in L and N, Hot pluggable
Voltage (default) / (adjustable range)245 VDC / 194 - 290 VDC
Power (maximum @nominal input)2400 W 2)1200 W 2)
Current (maximum @nominal output VDC)11,1 A 2)5,5 A 2)
Hold up time, maximum output power>10ms; VOUT > 95 VDC
Output featuresShort circuit proof, Over voltage Shutdown, Bulk DC output connection to M6 bolt
AC Mains Input Voltage (single phase)185 - 275 VAC95 - 140 VAC
AC Current (at nominal output voltage) (depending on module type)14-24 ARMS 4)
Frequency (default: sync range)47-53 & 57-63 Hz57-63 & 47-53 Hz
Frequency (set-able: sync range)47-53 Hz, 57-63 Hz or both (adaptive)
Power Factor / THD> 0.99 at 50% load or more / < 3.5%
DC Voltage nominal / extended range (no overload)3)204 - 290 VDC / 180 - 204 VDC
DC Current (maximum)13,3 A / 18 A during overload (15s)6,4 A / 9 A during overload (15s)
Input featuresFuse in L and N, Hot pluggable, Varistor, Hot pluggable AC input individual screw terminals 6 mm2 for L, N & PE Bulk DC input connection to M6 bolt
Support for connection to following controller (RJ45)Smartpack2, Smartpack S & Compack controllers
Efficiency>96% (mains mode (AC/AC and AC/DC)), >94% (inverter mode (DC/AC))
2 pole AC distribution (connection IEC 320-C13 sockets)3pc, 10A, OP characteristics (optional 4-8 A breaker with CS characteristics available)
Operating temperature-40 to +55°C (+40 to +131°F), humidity 5 - 95% RH non-condensing
Storage temperature-40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing
Dimensions[WxDxH] / Weight482 x 395 x 44mm (1U) (19 x 17 x 1,8”) / 6kg (13 lbs)
Electrical safetyEN 60950-1, EN 62040-1
EMCETSI EN 300 386 V.1.6.1, FCC CFR 47 Part 15 EN 61000-6-1/-2/-4/-5 EN62040-2 (Cat C1 emmisions, cat C2/C3 immunity)
EnvironmentETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3) Normal operating conditions as per IEC/EN 62040-3:2011 clause 4.2. Other operating conditions as per IEC 62040-3:2011 clause 4.3, must be advised 2011/65/EU (RoHS) & 2012/19/EU (WEEE)
1) Output voltage ranges configured in factory and have individual keying in top chassis 3) Reduced performance - no power boost and increased voltage THD on AC output.2) AC load has priority. Maximum available DC output power and current is dependent on instant AC load and AC input voltage; i.e maximum 1600W at full AC power and nominal input for 230VAC. 4) If DC voltage is pulled below 194 V the input current may increase above this level

Highlight: 3kVA 1phase Telecom Power System, 3kVA 220VDC rectiverter Integrated standalone, 3kVA 1phase rectiverter Integrated standalone

3kVA 1phase Telecom Power System, 3kVA 220VDC rectiverter Integrated standalone, 3kVA 1phase rectiverter Integrated standalone

Product Description

Eltek Rectiverter Integrated Standalone System 3kVA 1phase 220 VDC (Part No.:CTOR0201.003 CTOR0201.006 )

Applications

The rectiverter integrated standalone system can be used in application where

1 230/115Vac backup is needed in parallel with the 220Vdc backup .

The system can be integrated into an Eltek DC system and connected to the same controller as the 220Vdc systems

It can also be used as a standalone system connected to any available, 220Vdc source.

The total output power for both AC and DC output is limited to max 4kw, AC and DC output limits can be set according to the attached load.Where the limitation for AC load is set to max 3Kva.

TELECOM-MOBILE/WIRELESS

LTE/4G/WiMAX

Distributed antenna system

Broadband

Radio base stations/cell sites

RAILWAY & METRO INFRASTRUCTURE

Control & protection

Signaling

GSM-R

Safety Systems

POWER UTILITIES

Control & protection

SCADA system

Key Features

Compact design and simple installation

Single phase 230 or 115VAC input and output

48Vdc input and output

Up to 4 rectiverter modules

8KW total AC+DC output

Max 6kVA AC output

Max 4KW/ 8KW DC output

1 or 2 pole AC distribution options

1 Pole DC distribution option

Built in transfer technology

Techinical Data

Product Display

Related Products

Why Choose Us

Loading...